120A DC Immune Current Transformer 2500:1 0.2class

Structural parameter

ZMXQD05

120A DC immune current transformer


Main technical parameters

parameters

value

Operating frequency

50 Hz ~ 400 Hz

Operating temperature

-40℃ ~ 85℃

Relative humidity

≤95%

Rated primary current  Ip

5A

Maximum primary operating current Imax

120A

Testing current for DC component 120A/Root 2

<3%

Rated second current

2mA

Turns ratio

2500:1

Sampling resistor

≤20Ω

Accuracy class

0.2

power-frequency withstand voltage

3Kv/1min

Insulation resistance

>500M/500Vdc

 

Accuracy class

With the percentage(%)of Ip

5

20

100

120

Ratio Error (±%)

0.2

0.2

0.2

0.2

Phase Displacement (±ˊ)

15

15

15

15

Material List

No.                

material                

Spec.                

UL file number                

1                

Inner core                

Nanocrystalline  core                

/                

2                

Outer core                

Amorphous core                

/                

3                

Core shell                

PBT                

E238981                

4                

winding                

 2500T                

E258243                

5                

case                

Black                

E238981                

6                

Epoxy resin                

TXH-9201-10 epoxy resin insulating compound                

E196959                

7                

Leading wire                

UL1569, 26#AWG, 105, 300V                 

Red, black                

E315651                

8                

Tape                

Flame retardant,                

Environmental protection                

E165111                

Product Inquiry

φ11.5mm 100A DC Immune Current Transformer 2500:1 14.5mm thickness

φ12mm DC immune current transformer 2500:1 120A

φ27.5mm DC immune current transformer 2500:1 60A

Current transformer with DC immunity for energy meter

20A DC Immune Current Transformer 2000:1 1.0class